Scientist Solutions: Life Science Discussions
 Refer a Friend    Link To Us    Bookmark Us       

      
 » Home » Anatomy and Physiology » Electrophysiology » Troubleshooting an unusal problem

Other Topics
12/1/2008 06:49 PM
Outward Current in wild t ...
11/27/2008 02:03 AM
...about capacitance
11/18/2008 01:40 PM
Suction Electrodes out of ...
11/11/2008 02:35 AM
Fast single-channels (Nav ...
11/5/2008 05:06 PM
electrical noise
11/3/2008 02:03 PM
Which Pipette to use?
11/3/2008 01:33 PM
Technical electrophysiolo ...
10/29/2008 10:12 AM
...mini spontaneous curre ...
10/29/2008 10:23 AM
cell attached patch
10/7/2008 12:10 PM
Help with stimulation ele ...
10/7/2008 12:25 PM
Help with stimulation ele ...
9/28/2008 05:08 PM
I-V curve
9/26/2008 06:20 PM
No on this graph
9/24/2008 01:51 AM
Type of ATP salt
9/20/2008 04:20 PM
What is STEP and What is ...
9/9/2008 09:37 AM
Ventricular myocytes (car ...
9/2/2008 08:26 AM
cesium methansulfate inte ...
8/29/2008 11:05 AM
BSA foam in patch solutio ...
8/29/2008 10:19 AM
difficulty in forming who ...
8/29/2008 05:58 AM
Automated Electrophysiolo ...
8/22/2008 09:11 AM
Electrophysiology Trainin ...
8/20/2008 08:08 PM
intracellular solution in ...
8/20/2008 06:46 PM
glass capillary
8/13/2008 04:37 AM
Can EGTA increase intrace ...
8/12/2008 09:20 PM
iCBBE2009 international c ...
8/7/2008 02:25 PM
action potentials in whol ...
8/7/2008 02:44 PM
liquid junction potential
7/3/2008 08:26 AM
...should R-memb change i ...
6/26/2008 06:46 AM
How long till trashed?
5/26/2008 11:33 AM
Graficaly determination o ...
Subscribet to topic
Add Reply  Add New Topic  Add New Poll
bottom of page RSS Feed 

Topic Feed

 

Troubleshooting an unusal problem

 [View Printable]
Honna

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 1
Joined: Sep 17, 2008







 Send a personal messsage to Honna Reply with a quote from this post Go to the top of the page

Unusual problem here that I'm hoping someone may have encountered before.

My stimulating electrodes [1 FHC stainless steel, 1 FHC tungsten], when activated, generate a large number of bubbles that interfere with the stimulus artifact reaching the tissue. The amount or rate of bubble formation seems* to vary directly with the strength of stimulation.

Troubleshooting has led me to believe that hardware is most likely not the culprit (electrodes, wires, stimulus isolater have all been changed or checked) and that it may be a problem with the software.

I'm using mostly Axon laboratory materials: Recently updated pClamp V10.2.0.14 software connected to an Axon Instruments Digidata 1322A digitizer and a MultiClamp 700B, running through a BAK electronics Biphasic stimulus isolater. Strangely enough, the bubbles disappear when using V9 Clampex software.

Anybody run into a problem like this before, or have come across any bugs in the new Clampex V10.2.0.14 software, or at the very least have a suggestion on where to start or how to approach this??

Muchos gracias.

.........................

 Posted Sep 17, 2008, 15:48 PM
frasermoss

Frog Laureate

See
Similar
Scientists



View Blogs


Group: Admin
Posts: 724
Joined: Feb 22, 2005







 Send a personal messsage to frasermoss Reply with a quote from this post Go to the top of the page

Contact Axon Instruments (Molecular devices) through their support request form and explain your problem at

http://www.moleculardevices.com/cgi-bin/support_request.cgi

If the reply is not quick enough or unhelpful call them direct at 1-800-635-5577 (U.S. only) or +1 408-747-1700.


A colleague of mine was having problems with pClamp10 and a 700B amplifier this week when he was trying to perform P/N leak subtraction on whole cell patch recordings. The software was performing the leak subtraction and displaying a subtracted trace in Clampex, but the only the uncorrected trace was recorded and the corrected trace could not be viewed or analyzed in Clampfit.
So there do appear to be some bugs in the v10 right now.

It seems you may have isolated the source of the problem, so If v9 works for you I'd downgrade for now and acquire some data.

.........................
"Opportunity is missed by most people because it is dressed in overalls and looks like work". Edison

Posted Sep 17, 2008, 17:16 PM Last edited Sep 17, 2008, 17:16 PM by frasermoss