Scientist Solutions: Life Science Discussions
 Refer a Friend    Link To Us    Bookmark Us       

      
 » Home » Anatomy and Physiology » Electrophysiology » ...should R-memb change in wholle-Cell?

Other Topics
11/21/2008 02:06 AM
...about capacitance
11/18/2008 01:40 PM
Suction Electrodes out of ...
11/11/2008 02:35 AM
Fast single-channels (Nav ...
11/5/2008 05:06 PM
electrical noise
11/3/2008 02:03 PM
Which Pipette to use?
11/3/2008 01:33 PM
Technical electrophysiolo ...
10/29/2008 10:12 AM
...mini spontaneous curre ...
10/29/2008 10:23 AM
cell attached patch
10/7/2008 12:10 PM
Help with stimulation ele ...
10/7/2008 12:25 PM
Help with stimulation ele ...
9/28/2008 05:08 PM
I-V curve
9/26/2008 06:20 PM
No on this graph
9/24/2008 01:51 AM
Type of ATP salt
9/20/2008 04:20 PM
What is STEP and What is ...
9/17/2008 05:31 PM
Troubleshooting an unusal ...
9/9/2008 09:37 AM
Ventricular myocytes (car ...
9/2/2008 08:26 AM
cesium methansulfate inte ...
8/29/2008 11:05 AM
BSA foam in patch solutio ...
8/29/2008 10:19 AM
difficulty in forming who ...
8/29/2008 05:58 AM
Automated Electrophysiolo ...
8/22/2008 09:11 AM
Electrophysiology Trainin ...
8/20/2008 08:08 PM
intracellular solution in ...
8/20/2008 06:46 PM
glass capillary
8/13/2008 04:37 AM
Can EGTA increase intrace ...
8/12/2008 09:20 PM
iCBBE2009 international c ...
8/7/2008 02:25 PM
action potentials in whol ...
8/7/2008 02:44 PM
liquid junction potential
6/26/2008 06:46 AM
How long till trashed?
5/26/2008 11:33 AM
Graficaly determination o ...
5/5/2008 10:17 AM
intracellular recording
Subscribet to topic
Add Reply  Add New Topic  Add New Poll
bottom of page RSS Feed 

Topic Feed

 

...should R-memb change in wholle-Cell?

 [View Printable]
wanderer36

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 14
Joined: Dec 04, 2007







 Go to homepage of wanderer36 Send a personal messsage to wanderer36 Reply with a quote from this post Go to the top of the page


Hola

During one patch the membrane resistence should be over 1GO, and when open the cell to get the wholle cell, should this resistence decreased?

Thanks...

.........................
"Everything you can do its true" -La Casa del Cid-

 Posted Jun 19, 2008, 8:15 AM
Golden ball

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 15
Joined: Sep 06, 2006







 Send a personal messsage to Golden ball Reply with a quote from this post Go to the top of the page

Once you rapture the patch membrane (whole cell), the circuit resisitance is the sum of series resistance and the membrane resistance. Thus, I believe the resistance will be smaller than that measued in on-cell mode (G seal).

Actually in my case,
in on-cell mode: a few or some G ohms
in whole cell mode: from several hundreds M ohms to a few G ohms.

.........................

Posted Jun 19, 2008, 13:06 PM
wanderer36

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 14
Joined: Dec 04, 2007







 Go to homepage of wanderer36 Send a personal messsage to wanderer36 Reply with a quote from this post Go to the top of the page

...well, I patch neurons, and after open the cell, the resistence keep over one GOm, most of the time about three to four GOm, and the R-series decreased to about 20 to 40MO, and I get good currents. The point is that someone ask me why the membrane resistence keep so higt after open the cell, by the contrary it should decreased a lot, so I don´t know why and now I´m confused about that... Regards. [b]

.........................
"Everything you can do its true" -La Casa del Cid-

Posted Jun 30, 2008, 3:41 AM
Golden ball

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 15
Joined: Sep 06, 2006







 Send a personal messsage to Golden ball Reply with a quote from this post Go to the top of the page

As my opinion, your value of R-series seems to be too big. After the suitable Rs compensation, the voltage error would be some to several mV (if you measure a current amplitude >1 nA). This might give an impact to the current shape.

If I were you, I would calibrate the machine first, make the new solution, use a bigger size of the electrode (2 - 3 MO), and chek if the same thing happens or not. If the same happened, then this can be the reality in your experimental condition.

How about your base line at your holding potential? Such a high value, it must be close to zero. Does your pipette solution have KCl or CsCl?

Finally, do you use hematclit tube for the electrode? I have used it and the similar experience.

.........................

Posted Jun 30, 2008, 8:56 AM
wanderer36

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 14
Joined: Dec 04, 2007







 Go to homepage of wanderer36 Send a personal messsage to wanderer36 Reply with a quote from this post Go to the top of the page

...I don´t use hematclit tube; I think is becuse this experimental conditons. The zero line is ok, no so far from zero. The cell firing fine in Current clamp mode. Is only that I have not clear if there is normal that the membrane resistence keep over GOm even the cell is open and give good currents.



.........................
"Everything you can do its true" -La Casa del Cid-

Posted Jul 03, 2008, 8:31 AM