Scientist Solutions: Life Science Discussions
 Refer a Friend    Link To Us    Bookmark Us       

      
 » Home » Analytical Chemistry » Chromatography » Overly complex flow program? (RP-HPLC)

Other Topics
11/20/2008 09:31 PM
Melamine analysis
11/3/2008 11:56 AM
IEX-HPLC for peptide mapp ...
10/29/2008 11:06 PM
Empty Capsule Testing by ...
10/16/2008 09:07 AM
Trace GC + Fisons AS800 a ...
10/6/2008 11:07 AM
formic acid HPLC
9/14/2008 04:03 PM
Queries
9/12/2008 10:10 PM
Formic Acid Quantitation
9/10/2008 06:20 AM
Formic acid quantitation
9/10/2008 06:26 AM
GC - Pump down
9/4/2008 09:11 AM
Base line Problems
8/28/2008 09:05 AM
chromatogram shape and in ...
8/19/2008 07:35 AM
detergent and lipids in F ...
8/14/2008 01:34 PM
Auto injector errors
8/10/2008 12:50 AM
HPLC for peptides
7/18/2008 10:06 AM
thiocyanate
7/16/2008 10:23 PM
A Good Site for Chemical ...
6/17/2008 01:01 PM
New Chromatography Softwa ...
5/29/2008 08:43 AM
GC FID detector with high ...
5/28/2008 06:49 PM
Dionex PAD-2
5/27/2008 09:36 AM
Does different HPLC syste ...
5/19/2008 06:36 AM
RP-HPLC chromatograph int ...
4/22/2008 02:07 PM
GC baseline problems
3/30/2008 03:08 PM
SHimadzu autosampler Ques ...
3/24/2008 08:31 PM
HPLC separation of colla ...
3/17/2008 02:10 PM
Ultra Performance Liquid ...
3/17/2008 02:12 PM
RPHPLC/ separation of sma ...
3/10/2008 08:27 PM
Thermo Fisher Scientific ...
2/17/2008 11:24 AM
Flow analysis and Flow sy ...
2/11/2008 06:19 PM
Thermo Fisher Scientific ...
7/31/2007 10:37 AM
Chiral separation of Dexi ...
Subscribet to topic
Add Reply  Add New Topic  Add New Poll
bottom of page RSS Feed 

Topic Feed

 

Overly complex flow program? (RP-HPLC)

 [View Printable]
ike9898

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 7
Joined: Oct 18, 2007







 Send a personal messsage to ike9898 Reply with a quote from this post Go to the top of the page

I'm tweaking a method (RP-HPLC) so that I can get separation of about 23 amino acids I need to quantify. As I refine the method, I am tempted to add more and more steps, to really 'tighten up' the chromatogram. Is it considered 'bad form' to have a method with too many steps?

.........................

 Posted Dec 05, 2007, 21:01 PM
ike9898

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 7
Joined: Oct 18, 2007







 Send a personal messsage to ike9898 Reply with a quote from this post Go to the top of the page

I got an opinion on this topic from a career chromatographer; part of his reply: "putting more than 2 or 3 segments in a gradient is risky. The problem is that the conditions get harder and harder to reproduce if you change equipment, because of the washout and mixing characteristics of each instrument. If you will only use the method on a single instrument, you can get away with it. One of my colleagues did about 10 segments for a peptide separation and it was quite reproducible on a single instrument, so I know it works. So the bottom line is that it is bad form, but sometimes you gotta do what you gotta do to get the job done."

.........................

Posted Dec 06, 2007, 20:27 PM