Scientist Solutions: Life Science Discussions
 Refer a Friend    Link To Us    Bookmark Us       

      
 » Home » Analytical Chemistry » Chromatography » Trace GC + Fisons AS800 autosampler??

Other Topics
11/20/2008 09:31 PM
Melamine analysis
11/3/2008 11:56 AM
IEX-HPLC for peptide mapp ...
10/29/2008 11:06 PM
Empty Capsule Testing by ...
10/6/2008 11:07 AM
formic acid HPLC
9/14/2008 04:03 PM
Queries
9/12/2008 10:10 PM
Formic Acid Quantitation
9/10/2008 06:20 AM
Formic acid quantitation
9/10/2008 06:26 AM
GC - Pump down
9/4/2008 09:11 AM
Base line Problems
8/28/2008 09:05 AM
chromatogram shape and in ...
8/19/2008 07:35 AM
detergent and lipids in F ...
8/14/2008 01:34 PM
Auto injector errors
8/10/2008 12:50 AM
HPLC for peptides
7/18/2008 10:06 AM
thiocyanate
7/16/2008 10:23 PM
A Good Site for Chemical ...
6/17/2008 01:01 PM
New Chromatography Softwa ...
5/29/2008 08:43 AM
GC FID detector with high ...
5/28/2008 06:49 PM
Dionex PAD-2
5/27/2008 09:36 AM
Does different HPLC syste ...
5/19/2008 06:36 AM
RP-HPLC chromatograph int ...
4/22/2008 02:07 PM
GC baseline problems
3/30/2008 03:08 PM
SHimadzu autosampler Ques ...
3/24/2008 08:31 PM
HPLC separation of colla ...
3/17/2008 02:10 PM
Ultra Performance Liquid ...
3/17/2008 02:12 PM
RPHPLC/ separation of sma ...
3/10/2008 08:27 PM
Thermo Fisher Scientific ...
2/17/2008 11:24 AM
Flow analysis and Flow sy ...
2/11/2008 06:19 PM
Thermo Fisher Scientific ...
12/6/2007 08:09 PM
Overly complex flow progr ...
7/31/2007 10:37 AM
Chiral separation of Dexi ...
Subscribet to topic
Add Reply  Add New Topic  Add New Poll
bottom of page RSS Feed 

Topic Feed

 

Trace GC + Fisons AS800 autosampler??

 [View Printable]
Deuterium

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 3
Joined: Aug 28, 2006







 Send a personal messsage to Deuterium Reply with a quote from this post Go to the top of the page

I currently have an redundant Fisons AS800 autosampler and I was wondering if it could be installed on a Thermo GC. Till today most of the GC parts of Fisons, CarloErba and Thermo GC's are quite interchangeable, however I was wondering if this holds for autosamplers too. The new AS3000 supplied by Thermo is so very similar to the old Fisons AS800.

Is anyone out there working with a Fisons AS800 autosampler mounted on a ThermoQuest Trace GC??
If so do you need any special interface and does ChromCard software recognize the sampler?

Thanks for your help

Daniel

.........................

 Posted Aug 28, 2006, 17:36 PM
Deuterium

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 3
Joined: Aug 28, 2006







 Send a personal messsage to Deuterium Reply with a quote from this post Go to the top of the page

Ok just an update....
We have managed to instal the AS800 autosampler on the Trace GC.... it fits perfectly after buying the support and appropriate cables.
However, there is still one problem. The version of ChromCard (Version 2.4) only supports the AS2000 autosampler and although I was told that this should make it to control the AS800, I still do not manage to send and retrieve methods to and from the autosampler. It give me an error saying something like "Connection not possible". The funny thing is that if I give the clean command it works perfectly. The techies told me that I would have to set the autosampler sequence manually, however I am still convinced that something could be done.

Daniel

.........................

Posted Jan 21, 2007, 11:11 AM
henery

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 1
Joined: Oct 16, 2008







 Send a personal messsage to henery Reply with a quote from this post Go to the top of the page

said:
Do you have available an AS800 we could purchase from you. We are presently running on 5 years and having a few glitches and would be interested in a replacement/backup as800 for the aanylst 800.

pmohan@upei.ca

Thx,
Perry

.........................

Posted Oct 16, 2008, 9:58 AM