Scientist Solutions: Life Science Discussions
 Refer a Friend    Link To Us    Bookmark Us       

      
 » Home » Proteomics » Imaging Methods » SDS PAGE

Other Topics
12/4/2008 03:48 AM
Alternatives to boiling S ...
10/1/2008 05:50 PM
New technology paves way ...
5/30/2008 03:03 PM
SDS-PAGE: Proteins & dye ...
4/26/2008 05:30 PM
Ratio of stacking and sep ...
4/10/2008 01:30 PM
2D of large proteins
4/8/2008 08:55 AM
SDS PAGE stacking and res ...
8/23/2007 04:29 PM
Phosphoprotein Analaysis.
8/13/2007 04:29 PM
Glycosilated proteins
7/25/2007 01:34 AM
How do you stain your 2D ...
2/20/2007 09:51 PM
Infrared-based protein de ...
9/1/2006 08:10 PM
Ponceau red
8/9/2006 01:10 PM
Ettan DIGE system
7/27/2006 06:18 PM
Membrane channal 2D
5/4/2006 02:14 PM
Any 2D of 3t3 cells
4/24/2006 02:03 PM
Detecting Oxidized protei ...
3/28/2006 02:56 PM
SDS-PAGE problem
3/3/2006 06:13 PM
SDS-PAGE for low molecula ...
2/17/2006 12:24 PM
Detecting Glycosylated pr ...
1/18/2006 04:55 PM
Running 2D sample that is ...
1/2/2006 12:55 PM
Amplex Red Cholesterol qu ...
12/26/2005 12:04 PM
Sypro Ruby and Pro Q dimo ...
3/31/2005 06:54 PM
2d ANALYSIS NORMALISATION
1/28/2005 12:01 AM
Imaging Self Assembling M ...
1/27/2005 02:09 PM
SyproRuby flourescent met ...
Subscribet to topic
Add Reply  Add New Topic  Add New Poll
bottom of page RSS Feed 

Topic Feed

 

SDS PAGE

 [View Printable]
vaishali

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 1
Joined: Mar 13, 2006







 Send a personal messsage to vaishali Reply with a quote from this post Go to the top of the page

I am facing problem while running SDS PAGE. Stacking gel is shrinking and the wells are not forming properly. Bands are also not coming despite the enzyme is showing activity........Can anybody help me in sample preperation and appropriate percentage of gel for SDS PAGE for the protein having MW between 60Kd- 95KD
Thanks

.........................

Posted Mar 13, 2006, 12:34 PM
cornillon

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 18
Joined: Mar 01, 2006







 Send a personal messsage to cornillon Reply with a quote from this post Go to the top of the page

to prepare 10ml of stacking gel, I use:
6,8ml H2O
1,7ml 30% acrylamid mix
1,25ml 1M Tris (pH 6,8)
0,1ml SDS 10%
and just before use
0,01ml(/ml of gel needed) 10% ammonium persulfate and 0,001ml (idem) TEMED

It works well

.........................

Posted Mar 13, 2006, 13:53 PM
Nallapeta

Frog Egg

See
Similar
Scientists





Group: Member
Posts: 1
Joined: Mar 13, 2006







 Send a personal messsage to Nallapeta Reply with a quote from this post Go to the top of the page

be sure to drain out the water completely after resolving gel is poymerise and also do cast 10%gel for ur purpose
Do quantify the protein before u load onto gel

.........................

Posted Mar 14, 2006, 3:49 AM
Tracy

Member

See
Similar
Scientists





Group: Member
Posts: 225
Joined: Feb 09, 2006







 Send a personal messsage to Tracy Reply with a quote from this post Go to the top of the page

vaishali said:
I am facing problem while running SDS PAGE. Stacking gel is shrinking and the wells are not forming properly. Bands are also not coming despite the enzyme is showing activity........Can anybody help me in sample preperation and appropriate percentage of gel for SDS PAGE for the protein having MW between 60Kd- 95KD
Thanks


Sometimes if the APS is not fresh, then the gel can't form properly. Make sure to use good APS.

.........................

Posted Mar 20, 2006, 21:08 PM